Fox ESS M1 Close Fault / M2 Close Fault
M1 Close Fault and M2 Close Fault report a problem with one of the grid relays inside your Fox ESS. These relays physically connect and disconnect the inverter from the mains. The fault is raised when the inverter checks a relay and finds it stuck, welded or not behaving as expected, so it refuses to run. Because a relay that cannot open is a safety risk, treat this as serious rather than a routine glitch.
What usually causes it
- A welded relay contact. The contacts inside M1 or M2 have fused together and can no longer open, so the inverter cannot isolate itself from the grid.
- A stuck or mechanically failed relay. The relay does not switch cleanly, often after long service or repeated heavy switching.
- A one-off internal glitch. Occasionally a single failed self-check trips the fault and a clean power cycle clears it for good.
- An internal control or driver fault on the relay circuit, which only a technician can confirm.
How to handle it safely
- Do one controlled power cycle. Shut the inverter down in order: turn off the AC isolator and grid breaker, switch the DC/PV isolator to off, then turn off the battery. Do not pull any DC connectors.
- Wait about 15 minutes. Let the unit fully de-energise and the internal capacitors discharge before you power it back up.
- Reconnect in reverse order. Turn the battery on, then the DC/PV isolator, then the grid and AC isolator, and let the inverter restart and run its self-checks.
- If the fault clears and stays clear, fine. If M1/M2 Close Fault returns, the relay has mechanically failed. Stop operating the inverter and call your installer. Do not keep cycling power to force it on.
Related Fox ESS codes
FAQ
Is it safe to keep using my inverter after an M1 or M2 Close Fault?
No. A stuck or welded relay means the inverter may not be able to cut itself off from the grid if something else goes wrong. You can try one controlled power cycle, but if the fault returns you should stop using the system and call your installer rather than running it.
Can I just reset it a few times until it goes away?
No. One power cycle is fine to rule out a one-off glitch. If M1/M2 Close Fault keeps coming back, the relay has failed mechanically and repeated resets will not fix it. The inverter needs a qualified technician to repair or replace it.
Helpful guides
Correction, 25 September 2026: An earlier version listed S1/S2 Close Fault and Main Relay Open as other names for this alarm. They are separate Fox ESS alarms; Main Relay Open means a grid relay that stays open, the opposite of a stuck-closed relay.
Sources
- Fox ESS H1(G2)/AC1(G2) Series user manual, V1.0.8: alarm table, M1 Close Fault and M2 Close Fault ("The grid relay M1/M2 keep close"). S1 Close Fault and S2 Close Fault are separate entries for the S1 and S2 relays, and Main Relay Open is the opposite condition ("The grid relay keeps open"), so it is not covered by this page.